ANCM OUT

  -  

However, process failure error happens when the ASP.NET application fails lớn run on the server.

Bạn đang xem: Ancm out

At hostingvietnam.vn, we get requests on ASP.NET errors for our customers, as a part of our server Management Services.

Today, let’s see how our support Engineers fix the error for our customers.

Causes for HTTP Error 502.5 – Process Failure

In general, the 502.5 error occurs when the ASP.NET application is not running. However, from our expertise in managing server, our Windows Experts identify the common causes for the error as:

Incorrect deployment & architecture Missing .NET framework installation in the server. The application pool has no access to the .NET files. Incorrect path in web.config

Further, we kiểm tra the sự kiện log lớn find more information regarding the error. The sample error looks like:

*

How to lớn fix HTTP Error 502.5 – Process Failure

Recently one of our customers contacted as his website was showing HTTP Error 502.5 – Process Failure error. Let us discuss how our support Engineers resolved the error.

1. Wrong Deployment mode and architecture

The common reason for the error is the incorrect architecture or the deployment mode. On analyzing the hệ thống we found that the 64-bit .NET bộ vi xử lý core was installed.

On checking the .net files, the files were present in 32-bit architecture. So our support Engineers resolved the error by changing the architecture lớn the correct version.

We opened the .NET exe file và changed the Deployment mode to lớn Self-Contained.

Next, we changed the Target Runtime to win-x6. Finally, saved the changes.

Xem thêm: Học Tiếng Anh Qua Những Câu Nói Nổi Tiếng Của Steve Jobs, 33 Câu Thần Chú Truyền Cảm Hứng Của Steve Jobs

Changing the deployment will change the runtime to the application directory. So we always analyze the whole system and the impact it will create before changing the option.

Thus changing the option resolved the error.

2.The .NET framework not installed

Another reason for the error is that the .NET framework is not installed on the server. A few application requires framework libraries lớn run the application. The .NET vi xử lý core doesn’t tư vấn the desktop applications with a user interface.

Thus we install the .NET framework for our customers in the vps to resolve the error.

3. Incorrect path in web.config

The web.config contains variables LAUNCHER_PATH and LAUNCHER_ARGS. When IIS tries to run the application, it uses these variables to connect.

So our tư vấn Engineers địa chỉ cửa hàng the below code on the web.config tệp tin to publish the contains from the đầu ra folder.

Adding the lines will replace the variables with the exact path.

Xem thêm: Vtcomputer - Cao Ngoc Anh

Conclusion

In short, we have discussed the causes for the error HTTP Error 502.5 – Process Failure. Also, we have discussed how our support Engineers resolve the error.